In residential buildings, commercial spaces, and light industrial workshops, branch circuit protection is essential for preventing electrical overloads and short circuits. This MCB 4.5KA 1P DIN Rail Miniature Circuit Breaker is a standard modular low-voltage miniature circuit breaker designed for terminal power distribution systems. Built in conformity with the IEC 60898 standard, it offers dependable overcurrent protection and infrequent circuit switching under normal working conditions. For additional models, explore our Miniature Circuit Breaker product range.
Operating on AC 50Hz/60Hz power lines with a rated voltage of 230V for single-pole circuits (and up to 400V for multi-pole networks), this single pole 4.5kA MCB features a thermal-magnetic mechanism that combines bimetal overload protection with magnetic instantaneous short-circuit tripping. With standard 18mm modular pole width and DIN rail mounting, it provides a practical solution for electrical contractors, panel assemblers, and wholesale distributors.
● Pole Configuration: 1P (Single Pole)
● Rated Voltage: AC 230V
● Rated Frequency: 50Hz / 60Hz
● Breaking Capacity: 4.5kA
● Rated Current: 1A–63A
● Tripping Curves: Type B, C, D
● Mounting: Standard 35mm DIN Rail
● Standard Compliance: IEC 60898, GB 10963
Designed for dependable performance, easy installation, and commercial affordability, this MCB features a balanced structural design:
● Standard Thermal-Magnetic Tripping: Dual-action protection combining an inverse-time bimetallic strip for overload response and an electromagnetic coil for rapid short-circuit disconnection.
● Effective Arc Quenching Chamber: The 1P miniature circuit breaker 4.5kA is equipped with a multi-plate de-ionizing arc chute that splits and cools electrical arcs during fault interruptions.
● Flame-Retardant Engineering Enclosure: Molded from flame-retardant engineering plastic with good electrical insulation, heat resistance, and impact durability for standard distribution enclosures.
● Bi-Stable DIN Rail Clip: Designed with a sturdy mounting latch for quick, tool-free snap-on installation onto standard 35mm symmetrical DIN rails.
● Reliable Tunnel Clamp Terminals: Screw-clamped tunnel terminals provide solid connection for solid or stranded copper conductors up to 25mm².
● Clear Operational Markings: High-legibility front markings indicating rated current, operational voltage, breaking capacity, and connection schematics.
Electrical and mechanical specifications based on IEC 60898 testing requirements:
| Technical Parameter | Standard Specification |
| Standard Compliance | IEC 60898, GB 10963 |
| Rated Frequency | 50 Hz / 60 Hz AC |
| Pole Configurations | 1P (Single Pole), 2P, 3P, 4P |
| Rated Current (In) | 1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A |
| Rated Operating Voltage (Ue) | 1P: AC 230V; 2P/3P/4P: AC 400V |
| Rated Short-Circuit Breaking Capacity (Icn) | 4.5 kA (1A–63A); 6.0 kA for 1A–32A (IEC 60898) |
| Tripping Characteristic Curves | Type C (5–10 In), Type D (10–20 In), Type B (3–5 In) |
| Ambient Operating Temperature | -5°C to +40°C |
| Mounting Method | Standard 35mm Symmetrical DIN Rail (IEC 60715) |
| Protection Degree | IP20 (Terminals); IP40 (when mounted in enclosure) |
The product range includes 4.5kA and 6kA miniature circuit breaker configurations. Refer to the specific rated current and model when confirming the applicable breaking capacity.
Explore more options: 4.5kA and 6kA Miniature Circuit Breakers.
IEC 60898, Reference Temperature: 30°C ± 2°C
| Tripping Curve | Initial State | Test Current | Tripping Time Limit | Expected Result |
| All Curves (B, C, D) | Cold state | 1.13 In | t ≥ 1 hour | No Tripping (Continuous load) |
| All Curves (B, C, D) | Immediately after test | 1.45 In | t < 1 hour | Overload Tripping |
| All Curves (B, C, D) | Cold state | 2.55 In |
1s < t < 60s (In ≤ 32A) 1s < t < 120s (In > 32A) |
Overload Tripping |
| Type B Curve | Cold state | 3.00 In | t ≥ 0.1 s | No Instantaneous Trip |
| Type B Curve | Cold state | 5.00 In | t < 0.1 s | Instantaneous Trip |
| Type C Curve | Cold state | 5.00 In | t ≥ 0.1 s | No Instantaneous Trip |
| Type C Curve | Cold state | 10.0 In | t < 0.1 s | Instantaneous Trip |
| Type D Curve | Cold state | 10.0 In | t ≥ 0.1 s | No Instantaneous Trip |
| Type D Curve | Cold state | 20.0 In | t < 0.1 s | Instantaneous Trip |
Copper Conductors
| Rated Current | Nominal Cross-Section of Wire | Recommended Tightening Torque |
| 1A–6A | 1.0 mm² | 2.0 N·m |
| 10A | 1.5 mm² | 2.0 N·m |
| 16A, 20A | 2.5 mm² | 2.0 N·m |
| 25A | 4.0 mm² | 2.0 N·m |
| 32A | 6.0 mm² | 2.5 N·m |
| 40A, 50A | 10.0 mm² | 2.5 N·m |
| 63A | 16.0 mm² | 3.0 N·m |
This MCB 4.5KA 1P DIN Rail Miniature Circuit Breaker is designed for standard commercial, residential, and industrial sub-distribution networks:
● Residential Power Distribution: Main lighting branch lines, domestic socket circuits, water heaters, and household consumer units.
● Commercial Buildings & Shops: Retail store distribution boxes, office lighting panelboards, and small commercial electrical cabinets.
● Industrial & Workshop Distribution: Auxiliary machinery control power, small motor lines, and secondary circuit isolation.
● Construction & Temporary Site Power: Power distribution panels for temporary worksite lighting and utility power supply.
Discover our Miniature Circuit Breaker range for different branch circuit protection requirements.
For other low-voltage protection solutions, visit our Electrical Protection Devices category.
You can also explore MCB Accessories for compatible modular circuit breaker components.
Our MCB 4.5KA 1P DIN Rail Miniature Circuit Breakers are manufactured according to standard industrial quality procedures and applicable electrotechnical standards:
● Compliance Standards: IEC 60898, GB 10963.
● Product Certifications: CE Marking, CCC Certification.
● Quality System: Produced under standardized factory quality management routines.
Learn more about our product certificates and factory workshop.
● Incoming Raw Material Check: Verification of copper conductors, stamped metal parts, bimetals, and plastic molding materials.
● Assembly Line Verification: Proper placement of arc chutes, contact levers, and magnetic trip coils.
● Thermal Tripping Inspection: Calibration testing under simulated overload currents to verify tripping action.
● Instantaneous Trip Testing: Pulse testing to verify instantaneous tripping under short-circuit thresholds.
● Dielectric Strength Check: Standard insulation withstand voltage verification between poles and to ground.
● Visual & Packaging Inspection: Verification of markings, terminal screws, inner box packing, and export labels.
For electrical importers, wholesalers, and panel builders seeking modular circuit breakers, the following product and supply considerations are important:
| Evaluation Aspect | Product Supply Features | Selection Considerations |
| Design Standard | Standard modular design compliant with IEC 60898 | Check applicable standards and installation dimensions |
| Manufacturing | Factory production and assembly procedures | Confirm production capacity and batch requirements |
| Calibration Testing | Thermal and instantaneous trip testing | Review applicable inspection and test records |
| Terminal Construction | Screw-clamped tunnel terminals | Confirm conductor compatibility and tightening torque |
| OEM / Private Labeling | Laser printing and customized carton packaging options | Confirm logo artwork and packaging specifications |
| Supply Arrangement | Factory-direct supply options | Confirm order quantity, delivery terms, and pricing |
● Mounting: Snap onto standard 35mm symmetrical DIN rail (IEC 60715). Ensure the latch is securely engaged.
● Conductor Stripping: Strip wire insulation cleanly (approximately 10–11 mm) without damaging the conductor strands.
● Wiring Connection: Insert the conductor into the terminal chamber and tighten the terminal screw to the recommended torque.
● Operational Check: Manually toggle the handle ON and OFF several times before powering the circuit to confirm smooth mechanical operation.
● Routine Maintenance: Periodically check terminal screw tightness in distribution boards to maintain good electrical contact.
Installation and electrical maintenance should be performed by qualified personnel in accordance with applicable electrical safety regulations.
Standard export packaging designed for international freight transport:
| Pole Type | Inner Box Qty | Master Carton Qty | Carton Volume | Gross Weight / Carton |
| 1P (Single Pole) | 12 pcs / inner box | 240 pcs / master carton | 0.038 m³ | Approx. 21.5 kg |
| 2P (Double Pole) | 6 pcs / inner box | 120 pcs / master carton | 0.038 m³ | Approx. 21.5 kg |
| 3P (Three Pole) | 4 pcs / inner box | 80 pcs / master carton | 0.038 m³ | Approx. 21.5 kg |
| 4P (Four Pole) | 3 pcs / inner box | 60 pcs / master carton | 0.038 m³ | Approx. 21.5 kg |
Suitable for FCL/LCL ocean shipping, air cargo, and international courier delivery. Packaging quantities, carton dimensions, and shipment details can be confirmed according to the selected pole configuration.
When selecting a miniature circuit breaker supplier, distributors and electrical contractors generally need to evaluate product specifications, packaging requirements, quality inspection procedures, and delivery arrangements.
For this MCB 4.5KA 1P DIN Rail Miniature Circuit Breaker, product configuration and supply details can be confirmed according to the intended electrical distribution application.
Customers can contact our team to discuss technical requirements, product models, packaging arrangements, and export shipping details.
A1: Type C (5–10 In) is commonly used for general residential and commercial lighting circuits, sockets, and standard loads. Type D (10–20 In) is designed for circuits with higher inductive starting currents, such as small motors and transformers.
A2: The rated short-circuit breaking capacity is 4.5kA for the specified configuration. The product range also includes 6kA options for certain 1A–32A ratings according to IEC 60898. Please confirm the exact model and rating before selection.
A3: Yes. OEM laser printing for brand logos and model names, as well as customized carton packaging, can be discussed according to order quantities and customization requirements.
A4: For standard packaging, the MOQ is 240 pcs (1 carton). For customized OEM branding, the typical MOQ starts at 2,000 poles. Please confirm the final quantity with our sales team.
● Sample Support: Product samples are available for evaluation and testing. Contact our sales team for sample arrangements.
● Standard Warranty: 12-month standard factory warranty from the date of shipment against manufacturing defects under normal operating conditions.
● Defect Handling: Clear replacement terms for verified quality issues.
We offer OEM manufacturing services for brand distributors and importers:
● Specification Confirmation: Confirm pole count (1P/2P/3P/4P), rated current, and tripping curve requirements.
● Branding & Artwork Approval: Confirmation of laser logo marking, rating labels, and packaging design.
● Sample Confirmation: Pre-production sample review if requested.
● Batch Production & Packaging: Manufacturing, testing, and standard export carton packing.
To request a quotation for the MCB 4.5KA 1P DIN Rail Miniature Circuit Breaker, please provide the following information with your inquiry:
● 1. Pole Requirements: 1P, 2P, 3P, or 4P.
● 2. Rated Current & Quantity Breakdown: For example, 16A, 32A, or 63A with required quantities.
● 3. Tripping Curve: Type B, Type C, or Type D.
● 4. Packaging & Branding: Standard packaging or OEM custom logo.
● 5. Destination Port & Delivery Terms: FOB, CIF, or EXW.
Contact C-DADA to discuss your MCB 4.5KA 1P requirements. Send us your specifications and order quantity to receive product information and a quotation.
Send an Inquiry →Address
No. 171, Yezhuang Road, Zhuangxing Town, Fengxian District, Shanghai, China
Tel
Unlock Your Custom Electrical Solution in 24 Hours!
Why Inquire with a Top-Tier Chinese Manufacturer?
✅ Direct Factory Pricing
Cut middleman costs! As a ISO 9001-certified factory in China, we deliver premium MCCBs, MCBs, and solar DC breakers at competitive rates—backed by CE, KEMA, and ASTA certifications.
✅ 40+ Years of OEM/ODM Expertise
Modify casings, labels, or technical specs effortlessly. Our R&D team (60+ patents) handles:
Custom voltage/current ratings
Branded packaging
Fast prototyping (samples in 7 days)
✅ 3 Million+ Units Annual Capacity
No order too large or urgent! Our 52,400㎡ plant guarantees:
◆ 15-day lead times for bulk orders
◆ Flexible MOQs
◆ Strict ASTM/UL testing
✅ Global Compliance, Zero Hassle
We solve export barriers for 45+ countries:
RoHS/REACH documentation
Region-specific certifications
Solar DC breakers for EU green projects