Products
Thermal Adjustable Moulded Case Circuit Breaker
  • Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker
  • Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker
  • Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker
  • Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker
  • Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker
  • Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker
  • Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker
  • Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker
  • Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker

Thermal Adjustable Moulded Case Circuit Breaker

Model:DAM1 Series
Discover the CDADA DAM1 Series Thermal Adjustable Moulded Case Circuit Breaker from 贴the reliable factory, Shanghai DADA Electric—certified (ASTA, KEMA, CE) and adjustable thermal settings (70-100% In). Ideal for precise overload protection in industrial applications. Available in 3P/4P configurations up to 1600A at 400V/415V. Perfect for OEMs and bulk buyers.

The DAM1 Series Thermal Adjustable Moulded Case Circuit Breaker by Shanghai DADA Electric CO., LTD. is designed to meet world-class standards, providing robust protection against both overload and short-circuit conditions. With an adjustable thermal setting range of 70% to 100% of In, this breaker can be fine-tuned to match your specific application needs.

Available in 3P and 4P configurations, rated up to 1600A at 400V/415V, it comes with global certifications such as ASTA, KEMA, CE, CB, SEMKO, and RoHS, ensuring compliance across multiple regions.

Thermal Adjustable Moulded Case Circuit Breaker

Electrical parameters of DAM1 Thermal Adjustable Moulded Case Circuit Breaker

Thermal adjustable type MCCB (0.7-1)In

Photo

Model

code

Icu (KA)

Ics (KA)

Rated Current -In

Ui(V)

Ue(V)

Pole

Uimp(V)

Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker

DAM1-160

B

25

12.5

10- 12,5-16-20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 -125 - 160(150)A

750V

400/415V

3P / 4P

8000

N

35

26.25

S

50

37.5

Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker

DAM1-250

N

35

26.25

63 - 80-100-125 - 160(180) - 200(225) - 250(320)A

750V

400/415V

3P /4P

8000

S

50

37.5

H

65

48.75

G

85

51

Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker

DAM1-630(400)

N

35

26.25

250 - 315 (350)- 400 - 500 - 630A

750V

400/415V

3P /4P

8000

S

50

37.5

H

70

52.5

G

85

52.5

Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker

DAM1-800

N

35

35

400 - 500 - 630 (700)- 800 -1000A

750V

400/415V

3P /4P

8000

S

50

37.5

H

70

52.5

G

85

52.5

Thermal Adjustable Moulded Case Circuit Breaker

DAM1-1600

S

65

50

800 -1000 - 1250 - 1600A

750V

400V

3P / 4P

8000

H

85

50

G

100

50


Key Specifications

Thermal Adjustable Moulded Case Circuit Breaker

Model: DAM1 Series Thermal Adjustable MCCB

Type: Moulded Case Circuit Breaker (MCCB)

Poles: 3P / 4P

Rated Voltage (Ue): 400V / 415V AC

Rated Current (In): 16A – 1600A

Adjustable Thermal Setting: 70% - 100% In

Certifications: ASTA, KEMA, CE, CB, SEMKO, RoHS

Frame Sizes: 6 frame sizes

Additional Features: Push-to-trip button, separate main and arcing contacts

MCCB Rated Current

(A)

Thermal Trip Setting Min

(0.7In)

Thermal Trip Setting Max

(1In)

Adjustable Range

(0.7–1In)

16

11.2

16

11.2–16

32

22.4

32

22.4–32

63

44.1

63

44.1–63

100

70

100

70–100

250

175

250

175–250

400

280

400

280–400

630

441

630

441–630

800

560

800

560–800

1250

875

1250

875–1250

1600

1120

1600

1120–1600


Working Principle & Protection Mechanism

★ Thermal Protection (Overload)

The thermal element within the DAM1 series uses a bimetallic strip that bends when heated by sustained overcurrent (> rated current). By adjusting the thermal setting between 70% and 100% of In, users can tailor the breaker’s response time to prevent nuisance trips while ensuring effective protection.

★ Push-to-Trip Button

For testing purposes, the push-to-trip button allows manual tripping of the breaker, verifying its operational integrity without needing to induce an actual fault condition.

★ Separate Main and Arcing Contacts

To enhance durability and performance, the DAM1 series features separate main and arcing contacts. This design ensures that the main contacts are protected during high-current events, prolonging the lifespan of the breaker.


Application Scenarios

The DAM1 Thermal Adjustable Moulded Case Circuit Breaker (MCCB) is ideal for a wide range of applications where precise control over overload protection is essential. These include:

★ Industrial Plants: Ensuring stable operation in steel mills, chemical plants, and oil platforms.

★ Commercial Buildings: Protecting electrical systems in shopping malls, office buildings, and hotels.

★ Utilities: Reliable distribution in substations and power grids.

★ Data Centers: Maintaining uptime in critical IT infrastructure.

Thermal Adjustable Moulded Case Circuit Breaker

Why choose CDADA?

1. We have professional R & D team, have standard development process. Can provide excellent customized service.

Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker

Thermal Adjustable Moulded Case Circuit Breaker

2. We produce circuit breaker by automatic production line, Now, we have 6 automatic production lines. And daily capacity is more than 1000pcs.

Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker

3. We have fully functional laboratory, our laboratory can witnessed laboratory , we can done thermal load, magnetic, and tripping limit, mechanism life, EMC in our laboratory.

Thermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit BreakerThermal Adjustable Moulded Case Circuit Breaker

4. Having obtained CB,CE,SEMKO,KEMA, ASTA,ROHS,SASO,CCC global

Thermal Adjustable Moulded Case Circuit Breaker

FAQs

Q1: What is the adjustable thermal setting range for the DAM1 MCCB?

A1: The thermal setting on the DAM1 series can be adjusted between 70% and 100% of In, allowing for precise control over overload protection.


Q2: Can the DAM1 Thermal Adjustable Moulded Case Circuit Breaker be used in both 3-pole and 4-pole configurations?

A2: Yes, the DAM1 series is available in both 3P and 4P configurations, making it suitable for various applications.


Q3: Does the DAM1 MCCB come with any additional features for testing or maintenance?

A3: Yes, the DAM1 series includes a push-to-trip button for easy testing and verification of the breaker's functionality without inducing a fault condition.


Q4: How does the DAM1 MCCB handle short circuits?

A4: The DAM1 series includes a magnetic trip mechanism that provides instantaneous protection against short circuits, ensuring rapid disconnection of fault currents.


Q5: Are there any accessories available for the DAM1 MCCB?

A5: Yes, a wide range of accessories is available, including alarm contacts, auxiliary contacts, undervoltage releases, and electric operating mechanisms, enhancing the flexibility and functionality of the breaker.
Hot Tags: Thermal Adjustable Moulded Case Circuit Breaker, China, Manufacturer, Supplier, Factory
Send Inquiry
Contact Info

Unlock Your Custom Electrical Solution in 24 Hours!

Why Inquire with a Top-Tier Chinese Manufacturer?

✅ Direct Factory Pricing

Cut middleman costs! As a ISO 9001-certified factory in China, we deliver premium MCCBs, MCBs, and solar DC breakers at competitive rates—backed by CE, KEMA, and ASTA certifications.

✅ 40+ Years of OEM/ODM Expertise

Modify casings, labels, or technical specs effortlessly. Our R&D team (60+ patents) handles:

Custom voltage/current ratings

Branded packaging

Fast prototyping (samples in 7 days)

✅ 3 Million+ Units Annual Capacity

No order too large or urgent! Our 52,400㎡ plant guarantees:

◆ 15-day lead times for bulk orders

◆ Flexible MOQs

◆ Strict ASTM/UL testing

✅ Global Compliance, Zero Hassle

We solve export barriers for 45+ countries:

RoHS/REACH documentation

Region-specific certifications

Solar DC breakers for EU green projects

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.Privacy Policy
RejectAccept