Products
SACE Moulded Case Circuit Breaker
  • SACE Moulded Case Circuit BreakerSACE Moulded Case Circuit Breaker

SACE Moulded Case Circuit Breaker

Wholesale certified SACE Moulded Case Circuit Breaker directly from CDADA factory for heavy-duty industrial AC power protection. Designed with a compact SACE frame and up to 85kA breaking capacity, it ensures easy installation and dependable overload safety for global switchgear projects and OEM procurement.

    DADA Electric is a professional manufacturer and supplier of low-voltage circuit protection products. The CDADA DAM1 Series AC Moulded Case Circuit Breaker provides a flexible solution for customers sourcing a SACE Moulded Case Circuit Breaker for industrial and commercial power distribution systems. With rated currents from 10A to 1600A and an optional motorized operating mechanism (D), the DAM1 series supports different circuit protection and electrical operation requirements. Contact CDADA for manufacturer-direct product information, model selection and quotation.

    The CDADA DAM1 Series AC Moulded Case Circuit Breaker is an advanced, high-performance low-voltage electrical protection apparatus engineered in strict compliance with international electrotechnical standards (IEC 60947-2, GB/T 14048.2). Built upon the proven SACE compact modular architecture, the DAM1 series covers rated operational currents from 10A up to 1600A across 6 distinct frame sizes (S1 125A, S2 160A, S3 250A, S4 400A/630A, S5 800A, and S6 1250A/1600A) for three-phase AC 50Hz/60Hz distribution systems with rated operational voltages up to AC 690V.

    With a rated insulation voltage (Ui) up to 800V, the DAM1 series provides reliable overcurrent, short-circuit, and undervoltage protection for main power incoming cabinets, branch distribution lines, and motor feeders. Circuit breakers rated up to 400A can also serve as direct, infrequent starters and thermal-magnetic protectors for three-phase squirrel-cage induction motors. The series supports versatile mounting configurations—including vertical/horizontal panel mounting, front panel connection, rear stud connection, plug-in base, draw-out cradle, and standard 35mm DIN rail mounting for S1/S2 frames with dedicated clips.

    CDADA DAM1 Series AC Moulded Case Circuit Breaker

    Core Product Features & Selling Points

    The DAM1 (SACE architecture) series is engineered to deliver distinct commercial and technical benefits:

    ● SACE Space-Saving Architecture: Compact dimensions (10%–20% smaller and lighter than standard domestic MCCBs) allow switchboard builders to design smaller enclosures, optimize busbar routing, and reduce international freight shipping costs.

    ● High Breaking Capacity up to 85kA: Available across 5 performance classes—B (25kA), N (36kA), S (50kA), H (65/70kA), and G (85kA)—delivering superior fault interruption capability for demanding industrial grids and main incoming panels.

    ● 35mm DIN Rail Mountability (S1 & S2 Frames): 125A and 160A frame sizes can be directly snapped onto standard 35mm DIN rails (EN 50022 / IEC 60715) using dedicated snap-on adaptor clips, eliminating panel drilling and cutting installation time by 50%.

    ● Flexible Thermal-Magnetic & Electronic Protection: Standard dual-action thermal-magnetic release with bimetallic inverse-time overload response, or the ST110-H intelligent electronic trip unit featuring MCU processing, 60%–100% current bar indicator, and ground fault protection.

    ● Modular Internal & External Accessories: Snap-in accessory compartments allow fast field installation of shunt releases (MX), undervoltage releases (MN), auxiliary contacts (OF), alarm switches (SD), rotary handles (Z), and motorized drives (D).

    DAM1 Series MCCB product features and accessories

    Technical Specifications & Performance Data

    Key electrical and mechanical parameters certified in accordance with IEC 60947-2 standards:

    Technical Parameter

    Standard Specification

    Standard Compliance

    IEC 60947-1, IEC 60947-2, GB/T 14048.1, GB/T 14048.2

    Rated Voltage & Frequency

    Ue = AC 380V / 400V / 660V / 690V, 50Hz / 60Hz

    Rated Insulation Voltage (Ui)

    AC 400V (S1, S2 frames); AC 690V / 800V (S3, S4, S5, S6 frames)

    Current Span & Frame Sizes

    10A to 1600A across S1 (125), S2 (160), S3 (250), S4 (400/630), S5 (800), S6 (1250/1600)

    Pole Configurations

    1P (160/1P), 2P (200/2P), 3P (All frames), 4P (3N, 4, 4B Neutral types)

    Breaking Capacity Classes

    B (Basic 25kA), N (Normal 36kA), S (Standard 50kA), H (High 65/70kA), G (Highest 85kA)

    Protection Release Options

    Distribution Protection (10 In ± 20%), Motor Protection (12 In ± 20%), ST110-H Electronic

    Mounting & Wiring Methods

    Fixed (Front / Rear stud), Plug-in base, Draw-out cradle, 35mm DIN rail (S1/S2)

    Frame Sizes & Short-Circuit Breaking Capacity Ratings (Icu / Ics at AC 400V / 690V)

    Frame Model (SACE)

    Rated Current (In)

    Poles

    Standard Class (B/N)

    High Class (S / H / G)

    Flashover

    DAM1-125 (S1)

    10A – 125A

    3P, 4P

    25 kA / 18 kA (B)

    36 kA / 25 kA (N), 50/35 kA (S)

    ≤ 50 mm

    DAM1-160 (S2)

    10A – 160A

    1P, 3P, 4P

    36 kA / 25 kA (N)

    50 kA / 35 kA (S), 65/45 kA (H)

    ≤ 50 mm

    DAM1-250 (S3)

    125A – 250A

    2P, 3P, 4P

    36 kA / 25 kA (N)

    50 kA / 35 kA (S), 65/45 kA (H)

    ≤ 50 mm

    DAM1-400 (S4)

    250A – 400A

    3P, 4P

    50 kA / 35 kA (S)

    65 kA / 45 kA (H), 85/50 kA (G)

    ≤ 100 mm

    DAM1-630 (S4)

    400A – 630A

    3P, 4P

    50 kA / 35 kA (S)

    65 kA / 45 kA (H), 85/50 kA (G)

    ≤ 100 mm

    DAM1-800 (S5)

    630A – 800A

    3P, 4P

    50 kA / 35 kA (S)

    70 kA / 50 kA (H), 85/50 kA (G)

    ≤ 100 mm

    DAM1-1250 (S6)

    800A – 1250A

    3P

    50 kA / 35 kA (S)

    70 kA / 50 kA (H)

    ≤ 100 mm

    DAM1-1600 (S6)

    1250A – 1600A

    3P

    50 kA / 35 kA (S)

    70 kA / 50 kA (H)

    ≤ 100 mm

    DAM1 MCCB frame sizes and breaking capacity ratings

    Typical Applications & Industry Sectors

    Engineered for demanding electrical environments, the DAM1 Series AC Moulded Case Circuit Breaker meets the installation needs of small power users all the way to heavy industrial substations:

    ● Industrial Manufacturing: Main incoming power, sub-distribution panels, and machinery protection in steel mills, chemical plants, and automotive factories.

    ● Commercial Buildings & HVAC: Floor distribution boards, lighting mains, and central chiller units in commercial skyscrapers, malls, and hospitals.

    ● Motor Control Centers (MCC): Direct-on-line starting, short-circuit protection, and thermal overload safeguard for heavy induction pumps, fans, and compressors.

    ● Data Centers & Critical Power: Main incoming and outgoing power distribution for uninterruptible power supplies (UPS) and backup generator switchboards.

    DAM1 Series MCCB applications in industrial and commercial power systems

    5. Standards, Certifications & Factory Quality Assurance

    Manufactured under strict ISO 9001 certified workflows with 100% factory calibration:

    ● Compliance & Certification: Fully compliant with IEC 60947-1, IEC 60947-2, GB/T 14048.1, GB/T 14048.2; certified with CE and CCC.

    ● Incoming Material Inspection: High-precision conductivity tests on copper conductors, contact tips, bimetallic elements, and flame-retardant molding plastics.

    ● 100% Electrical Calibration: Constant-current thermal bath testing and high-current magnetic pulse threshold validation on every unit.

    ● 2500V Dielectric Withstand Test: High-voltage insulation testing phase-to-phase, across open contacts, and to earth before packaging.

    Please confirm the applicable certificates and inspection reports for the specific model before placing an order.

    DAM1 Series circuit breaker quality inspection

    Sourcing & Manufacturing Advantages

    Electrical contractors, panel builders, and international distributors select the DAM1 Series AC Moulded Case Circuit Breaker for its superior design and strong commercial advantages:

    Evaluation Factor

    CDADA Factory Direct Supply

    Generic Sourced MCCB

    SACE Compact Form Factor

    10% to 20% smaller than standard MCCBs, saving valuable switchboard space

    Bulky domestic frames requiring larger enclosures

    High Breaking Capacity up to 85kA

    Complete breaking classes B, N, S, H, G up to 85kA at 400V

    Limited breaking options restricted to 25kA/35kA

    35mm DIN Rail Mountability

    S1 (125A) and S2 (160A) frames support direct DIN rail mounting with clip

    Fixed panel drill-and-tap mounting only

    Electronic Trip Unit Option

    ST110-H intelligent MCU electronic release with digital LED bar and alarms

    Basic fixed thermal-magnetic trip units only

    Commercial Competitiveness

    Direct factory pricing with high margin potential and fast batch delivery

    Multi-tier agent markups

    CDADA DAM1 Series circuit breaker product details

    Installation, Wiring Guidelines & Maintenance

    Flexible mounting and wiring configurations ensure seamless integration into international standard switchboards:

    ● Mounting Flexibility: Supports vertical or horizontal mounting on switchboard backplates without derating.

    ● Wiring Methods: Front connection (busbars or cable lugs), Rear stud connection (horizontal or vertical), Plug-in base, and Draw-out cradle.

    ● Phase Partitions: Interphase insulating barriers included in standard packaging must be fitted into top and bottom slots.

    ● Routine Maintenance: Clean dust from arc chute exhaust vents annually; inspect terminal screw tightness and contact wear after clearing fault currents.

    DAM1 MCCB installation and wiring configuration

    Comprehensive Accessory Range & Modularity

    A complete suite of modular internal and external accessories is available for flexible field assembly:

    ● Internal Accessories: Shunt Release (MX - remote electrical tripping), Undervoltage Release (MN - voltage drop protection), Auxiliary Switch (OF - ON/OFF status), and Alarm Switch (SD - trip fault indication).

    ● External Accessories: Manual Rotary Handle (Z - direct or door-interlocked with padlock), Motorized Mechanism (D - remote automatic opening/closing), Plug-in Base, Draw-out Cradle, and 35mm DIN Rail Adaptor Clips.

    For customers sourcing a SACE Moulded Case Circuit Breaker, the DAM1 motorized mechanism (D) is an optional accessory. Please confirm the required configuration and operating requirements with CDADA.

    Export Packaging & Shipping Specifications

    Heavy-duty export packaging designed for ocean container shipping, air freight, and multimodal transit:

    Frame Model & Pole

    Inner Box Qty

    Master Carton Qty

    Carton Volume

    Gross Weight / Carton

    DAM1-125 (S1 3P)

    1 pc / box

    24 pcs / carton

    0.035 m³

    Approx. 20.0 kg

    DAM1-160 (S2 3P)

    1 pc / box

    24 pcs / carton

    0.038 m³

    Approx. 21.5 kg

    DAM1-250 (S3 3P)

    1 pc / box

    12 pcs / carton

    0.045 m³

    Approx. 24.0 kg

    DAM1-400 (S4 3P)

    1 pc / box

    2 pcs / carton

    0.034 m³

    Approx. 16.0 kg

    DAM1-630 (S4 3P)

    1 pc / box

    2 pcs / carton

    0.038 m³

    Approx. 18.5 kg

    DAM1-800 (S5 3P)

    1 pc / box

    1 pc / carton

    0.036 m³

    Approx. 14.0 kg

    DAM1-1250 (S6 3P)

    1 pc / wooden crate

    1 pc / crate

    0.055 m³

    Approx. 24.0 kg

    DAM1-1600 (S6 3P)

    1 pc / wooden crate

    1 pc / crate

    0.065 m³

    Approx. 28.0 kg

    Global Export Experience & Customer Cooperation

    When importing the DAM1 Series AC Moulded Case Circuit Breaker for overseas commercial and industrial switchgear projects, clients benefit from proven manufacturing consistency and dedicated engineering support across more than 40 countries:

     " We selected CDADA DAM1 series SACE MCCBs (160A, 250A, and 400A frames) for our modular commercial distribution boards. The compact frame dimensions saved significant cabinet space, and the high breaking capacity of 70kA satisfied strict project safety requirements."

    CDADA DAM1 Series MCCB product range

    Frequently Asked Questions (FAQ)

    Q1: How do I select the appropriate breaking capacity class (B, N, S, H, G)?

    A1: Class B (25kA) and Class N (36kA) are designed for commercial sub-distribution and branch circuits. Class S (50kA) is recommended for standard industrial distribution boards and motor control centers. Class H (65/70kA) and Class G (85kA) are designed for main incoming switchboards situated close to high-capacity step-down transformers.

    Q2: Which DAM1 frames support standard 35mm DIN rail mounting?

    A2: S1 frame (DAM1-125) and S2 frame (DAM1-160) support direct 35mm DIN rail mounting (EN 50022 / IEC 60715) with dedicated snap-on adaptor clips, saving installation time in modular distribution boxes.

    Q3: What are the differences between 4-pole Neutral configurations (3N, 4, 4B)?

    A3: 3N: 3-pole breaker with an unswitched solid Neutral terminal bar; 4: 4-pole breaker where the Neutral pole switches synchronously without overcurrent protection; 4B: 4-pole breaker where the Neutral pole switches synchronously and is fully equipped with overcurrent protection.

    Q4: Can the DAM1 Series be supplied as a SACE Moulded Case Circuit Breaker?

    A4: The DAM1 Series can be equipped with an optional motorized mechanism (D) for electrical operation. Please confirm the required model and mechanism configuration when making an inquiry.

    Q5: What is the difference between a motorized mechanism and a shunt release?

    A5: The motorized mechanism (D) provides an electrical operating arrangement, while the shunt release (MX) is used for remote electrical tripping. They perform different functions and should be selected according to the application.

    Warranty & OEM Customization Service

    ● Standard Factory Warranty: 18-month warranty from date of shipment or 12-month from installation date against manufacturing defects under normal operating conditions.

    ● Laser Branding & Private Labeling: High-precision laser engraving of customer brand logo, custom model codes, QR traceability codes, and certification marks.

    ● Auxiliary Pre-Assembly: Factory pre-installation of specified shunt releases, undervoltage coils, auxiliary contacts, and motorized mechanisms.

    ● Customized Packaging: Customized inner color boxes, master export cartons, and localized multi-language instruction manuals.

    Commercial Procurement & RFQ Quick Checklist

    To receive a prompt, detailed quotation within 24 hours, please provide the following basic specifications in your inquiry:

    Inquiry Parameter

    Customer Specification / Options

    1. Model & Frame Size

    e.g. DAM1-125S, DAM1-160H, DAM1-250S, DAM1-400H, DAM1-630G, DAM1-800G, DAM1-1600S

    2. Pole Configuration

    1P, 2P, 3P, or 4P (specify Neutral type 3N, 4, or 4B)

    3. Rated Current & Quantity

    e.g. 100A (200 pcs), 160A (150 pcs), 250A (100 pcs), 630A (50 pcs)

    4. Breaking Capacity Class

    B (25kA) / N (36kA) / S (50kA) / H (65/70kA) / G (85kA)

    5. Protection Release Type

    Thermal-Magnetic (Standard) or ST110-H Electronic Microprocessor

    6. Selected Accessories

    Shunt release (voltage), Auxiliary/Alarm contact, Rotary handle, Motorized drive, DIN clip

    7. Target Trade Terms

    FOB Ningbo / Shanghai, CIF destination port, or EXW

    Request a DAM1 Circuit Breaker Quotation

    Looking for a reliable SACE Moulded Case Circuit Breaker supplier? Contact CDADA to discuss DAM1 Series models, optional motorized mechanisms, technical requirements and factory-direct supply.

    Send an Inquiry
    Send Inquiry
    Contact Info

    Unlock Your Custom Electrical Solution in 24 Hours!

    Why Inquire with a Top-Tier Chinese Manufacturer?

    ✅ Direct Factory Pricing

    Cut middleman costs! As a ISO 9001-certified factory in China, we deliver premium MCCBs, MCBs, and solar DC breakers at competitive rates—backed by CE, KEMA, and ASTA certifications.

    ✅ 40+ Years of OEM/ODM Expertise

    Modify casings, labels, or technical specs effortlessly. Our R&D team (60+ patents) handles:

    Custom voltage/current ratings

    Branded packaging

    Fast prototyping (samples in 7 days)

    ✅ 3 Million+ Units Annual Capacity

    No order too large or urgent! Our 52,400㎡ plant guarantees:

    ◆ 15-day lead times for bulk orders

    ◆ Flexible MOQs

    ◆ Strict ASTM/UL testing

    ✅ Global Compliance, Zero Hassle

    We solve export barriers for 45+ countries:

    RoHS/REACH documentation

    Region-specific certifications

    Solar DC breakers for EU green projects

    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept