DADA Electric is a professional manufacturer and supplier of low-voltage circuit protection products. The CDADA DAM1 Series AC Moulded Case Circuit Breaker provides a flexible solution for customers sourcing a SACE Moulded Case Circuit Breaker for industrial and commercial power distribution systems. With rated currents from 10A to 1600A and an optional motorized operating mechanism (D), the DAM1 series supports different circuit protection and electrical operation requirements. Contact CDADA for manufacturer-direct product information, model selection and quotation.
The CDADA DAM1 Series AC Moulded Case Circuit Breaker is an advanced, high-performance low-voltage electrical protection apparatus engineered in strict compliance with international electrotechnical standards (IEC 60947-2, GB/T 14048.2). Built upon the proven SACE compact modular architecture, the DAM1 series covers rated operational currents from 10A up to 1600A across 6 distinct frame sizes (S1 125A, S2 160A, S3 250A, S4 400A/630A, S5 800A, and S6 1250A/1600A) for three-phase AC 50Hz/60Hz distribution systems with rated operational voltages up to AC 690V.
With a rated insulation voltage (Ui) up to 800V, the DAM1 series provides reliable overcurrent, short-circuit, and undervoltage protection for main power incoming cabinets, branch distribution lines, and motor feeders. Circuit breakers rated up to 400A can also serve as direct, infrequent starters and thermal-magnetic protectors for three-phase squirrel-cage induction motors. The series supports versatile mounting configurations—including vertical/horizontal panel mounting, front panel connection, rear stud connection, plug-in base, draw-out cradle, and standard 35mm DIN rail mounting for S1/S2 frames with dedicated clips.
The DAM1 (SACE architecture) series is engineered to deliver distinct commercial and technical benefits:
● SACE Space-Saving Architecture: Compact dimensions (10%–20% smaller and lighter than standard domestic MCCBs) allow switchboard builders to design smaller enclosures, optimize busbar routing, and reduce international freight shipping costs.
● High Breaking Capacity up to 85kA: Available across 5 performance classes—B (25kA), N (36kA), S (50kA), H (65/70kA), and G (85kA)—delivering superior fault interruption capability for demanding industrial grids and main incoming panels.
● 35mm DIN Rail Mountability (S1 & S2 Frames): 125A and 160A frame sizes can be directly snapped onto standard 35mm DIN rails (EN 50022 / IEC 60715) using dedicated snap-on adaptor clips, eliminating panel drilling and cutting installation time by 50%.
● Flexible Thermal-Magnetic & Electronic Protection: Standard dual-action thermal-magnetic release with bimetallic inverse-time overload response, or the ST110-H intelligent electronic trip unit featuring MCU processing, 60%–100% current bar indicator, and ground fault protection.
● Modular Internal & External Accessories: Snap-in accessory compartments allow fast field installation of shunt releases (MX), undervoltage releases (MN), auxiliary contacts (OF), alarm switches (SD), rotary handles (Z), and motorized drives (D).
Key electrical and mechanical parameters certified in accordance with IEC 60947-2 standards:
|
Technical Parameter |
Standard Specification |
|
Standard Compliance |
IEC 60947-1, IEC 60947-2, GB/T 14048.1, GB/T 14048.2 |
|
Rated Voltage & Frequency |
Ue = AC 380V / 400V / 660V / 690V, 50Hz / 60Hz |
|
Rated Insulation Voltage (Ui) |
AC 400V (S1, S2 frames); AC 690V / 800V (S3, S4, S5, S6 frames) |
|
Current Span & Frame Sizes |
10A to 1600A across S1 (125), S2 (160), S3 (250), S4 (400/630), S5 (800), S6 (1250/1600) |
|
Pole Configurations |
1P (160/1P), 2P (200/2P), 3P (All frames), 4P (3N, 4, 4B Neutral types) |
|
Breaking Capacity Classes |
B (Basic 25kA), N (Normal 36kA), S (Standard 50kA), H (High 65/70kA), G (Highest 85kA) |
|
Protection Release Options |
Distribution Protection (10 In ± 20%), Motor Protection (12 In ± 20%), ST110-H Electronic |
|
Mounting & Wiring Methods |
Fixed (Front / Rear stud), Plug-in base, Draw-out cradle, 35mm DIN rail (S1/S2) |
Frame Sizes & Short-Circuit Breaking Capacity Ratings (Icu / Ics at AC 400V / 690V)
|
Frame Model (SACE) |
Rated Current (In) |
Poles |
Standard Class (B/N) |
High Class (S / H / G) |
Flashover |
|
DAM1-125 (S1) |
10A – 125A |
3P, 4P |
25 kA / 18 kA (B) |
36 kA / 25 kA (N), 50/35 kA (S) |
≤ 50 mm |
|
DAM1-160 (S2) |
10A – 160A |
1P, 3P, 4P |
36 kA / 25 kA (N) |
50 kA / 35 kA (S), 65/45 kA (H) |
≤ 50 mm |
|
DAM1-250 (S3) |
125A – 250A |
2P, 3P, 4P |
36 kA / 25 kA (N) |
50 kA / 35 kA (S), 65/45 kA (H) |
≤ 50 mm |
|
DAM1-400 (S4) |
250A – 400A |
3P, 4P |
50 kA / 35 kA (S) |
65 kA / 45 kA (H), 85/50 kA (G) |
≤ 100 mm |
|
DAM1-630 (S4) |
400A – 630A |
3P, 4P |
50 kA / 35 kA (S) |
65 kA / 45 kA (H), 85/50 kA (G) |
≤ 100 mm |
|
DAM1-800 (S5) |
630A – 800A |
3P, 4P |
50 kA / 35 kA (S) |
70 kA / 50 kA (H), 85/50 kA (G) |
≤ 100 mm |
|
DAM1-1250 (S6) |
800A – 1250A |
3P |
50 kA / 35 kA (S) |
70 kA / 50 kA (H) |
≤ 100 mm |
|
DAM1-1600 (S6) |
1250A – 1600A |
3P |
50 kA / 35 kA (S) |
70 kA / 50 kA (H) |
≤ 100 mm |
Engineered for demanding electrical environments, the DAM1 Series AC Moulded Case Circuit Breaker meets the installation needs of small power users all the way to heavy industrial substations:
● Industrial Manufacturing: Main incoming power, sub-distribution panels, and machinery protection in steel mills, chemical plants, and automotive factories.
● Commercial Buildings & HVAC: Floor distribution boards, lighting mains, and central chiller units in commercial skyscrapers, malls, and hospitals.
● Motor Control Centers (MCC): Direct-on-line starting, short-circuit protection, and thermal overload safeguard for heavy induction pumps, fans, and compressors.
● Data Centers & Critical Power: Main incoming and outgoing power distribution for uninterruptible power supplies (UPS) and backup generator switchboards.
Manufactured under strict ISO 9001 certified workflows with 100% factory calibration:
● Compliance & Certification: Fully compliant with IEC 60947-1, IEC 60947-2, GB/T 14048.1, GB/T 14048.2; certified with CE and CCC.
● Incoming Material Inspection: High-precision conductivity tests on copper conductors, contact tips, bimetallic elements, and flame-retardant molding plastics.
● 100% Electrical Calibration: Constant-current thermal bath testing and high-current magnetic pulse threshold validation on every unit.
● 2500V Dielectric Withstand Test: High-voltage insulation testing phase-to-phase, across open contacts, and to earth before packaging.
Electrical contractors, panel builders, and international distributors select the DAM1 Series AC Moulded Case Circuit Breaker for its superior design and strong commercial advantages:
|
Evaluation Factor |
CDADA Factory Direct Supply |
Generic Sourced MCCB |
|
SACE Compact Form Factor |
10% to 20% smaller than standard MCCBs, saving valuable switchboard space |
Bulky domestic frames requiring larger enclosures |
|
High Breaking Capacity up to 85kA |
Complete breaking classes B, N, S, H, G up to 85kA at 400V |
Limited breaking options restricted to 25kA/35kA |
|
35mm DIN Rail Mountability |
S1 (125A) and S2 (160A) frames support direct DIN rail mounting with clip |
Fixed panel drill-and-tap mounting only |
|
Electronic Trip Unit Option |
ST110-H intelligent MCU electronic release with digital LED bar and alarms |
Basic fixed thermal-magnetic trip units only |
|
Commercial Competitiveness |
Direct factory pricing with high margin potential and fast batch delivery |
Multi-tier agent markups |
Flexible mounting and wiring configurations ensure seamless integration into international standard switchboards:
● Mounting Flexibility: Supports vertical or horizontal mounting on switchboard backplates without derating.
● Wiring Methods: Front connection (busbars or cable lugs), Rear stud connection (horizontal or vertical), Plug-in base, and Draw-out cradle.
● Phase Partitions: Interphase insulating barriers included in standard packaging must be fitted into top and bottom slots.
● Routine Maintenance: Clean dust from arc chute exhaust vents annually; inspect terminal screw tightness and contact wear after clearing fault currents.
A complete suite of modular internal and external accessories is available for flexible field assembly:
● Internal Accessories: Shunt Release (MX - remote electrical tripping), Undervoltage Release (MN - voltage drop protection), Auxiliary Switch (OF - ON/OFF status), and Alarm Switch (SD - trip fault indication).
● External Accessories: Manual Rotary Handle (Z - direct or door-interlocked with padlock), Motorized Mechanism (D - remote automatic opening/closing), Plug-in Base, Draw-out Cradle, and 35mm DIN Rail Adaptor Clips.
For customers sourcing a SACE Moulded Case Circuit Breaker, the DAM1 motorized mechanism (D) is an optional accessory. Please confirm the required configuration and operating requirements with CDADA.
Heavy-duty export packaging designed for ocean container shipping, air freight, and multimodal transit:
|
Frame Model & Pole |
Inner Box Qty |
Master Carton Qty |
Carton Volume |
Gross Weight / Carton |
|
DAM1-125 (S1 3P) |
1 pc / box |
24 pcs / carton |
0.035 m³ |
Approx. 20.0 kg |
|
DAM1-160 (S2 3P) |
1 pc / box |
24 pcs / carton |
0.038 m³ |
Approx. 21.5 kg |
|
DAM1-250 (S3 3P) |
1 pc / box |
12 pcs / carton |
0.045 m³ |
Approx. 24.0 kg |
|
DAM1-400 (S4 3P) |
1 pc / box |
2 pcs / carton |
0.034 m³ |
Approx. 16.0 kg |
|
DAM1-630 (S4 3P) |
1 pc / box |
2 pcs / carton |
0.038 m³ |
Approx. 18.5 kg |
|
DAM1-800 (S5 3P) |
1 pc / box |
1 pc / carton |
0.036 m³ |
Approx. 14.0 kg |
|
DAM1-1250 (S6 3P) |
1 pc / wooden crate |
1 pc / crate |
0.055 m³ |
Approx. 24.0 kg |
|
DAM1-1600 (S6 3P) |
1 pc / wooden crate |
1 pc / crate |
0.065 m³ |
Approx. 28.0 kg |
When importing the DAM1 Series AC Moulded Case Circuit Breaker for overseas commercial and industrial switchgear projects, clients benefit from proven manufacturing consistency and dedicated engineering support across more than 40 countries:
A1: Class B (25kA) and Class N (36kA) are designed for commercial sub-distribution and branch circuits. Class S (50kA) is recommended for standard industrial distribution boards and motor control centers. Class H (65/70kA) and Class G (85kA) are designed for main incoming switchboards situated close to high-capacity step-down transformers.
A2: S1 frame (DAM1-125) and S2 frame (DAM1-160) support direct 35mm DIN rail mounting (EN 50022 / IEC 60715) with dedicated snap-on adaptor clips, saving installation time in modular distribution boxes.
A3: 3N: 3-pole breaker with an unswitched solid Neutral terminal bar; 4: 4-pole breaker where the Neutral pole switches synchronously without overcurrent protection; 4B: 4-pole breaker where the Neutral pole switches synchronously and is fully equipped with overcurrent protection.
A4: The DAM1 Series can be equipped with an optional motorized mechanism (D) for electrical operation. Please confirm the required model and mechanism configuration when making an inquiry.
A5: The motorized mechanism (D) provides an electrical operating arrangement, while the shunt release (MX) is used for remote electrical tripping. They perform different functions and should be selected according to the application.
● Standard Factory Warranty: 18-month warranty from date of shipment or 12-month from installation date against manufacturing defects under normal operating conditions.
● Laser Branding & Private Labeling: High-precision laser engraving of customer brand logo, custom model codes, QR traceability codes, and certification marks.
● Auxiliary Pre-Assembly: Factory pre-installation of specified shunt releases, undervoltage coils, auxiliary contacts, and motorized mechanisms.
● Customized Packaging: Customized inner color boxes, master export cartons, and localized multi-language instruction manuals.
To receive a prompt, detailed quotation within 24 hours, please provide the following basic specifications in your inquiry:
|
Inquiry Parameter |
Customer Specification / Options |
|
1. Model & Frame Size |
e.g. DAM1-125S, DAM1-160H, DAM1-250S, DAM1-400H, DAM1-630G, DAM1-800G, DAM1-1600S |
|
2. Pole Configuration |
1P, 2P, 3P, or 4P (specify Neutral type 3N, 4, or 4B) |
|
3. Rated Current & Quantity |
e.g. 100A (200 pcs), 160A (150 pcs), 250A (100 pcs), 630A (50 pcs) |
|
4. Breaking Capacity Class |
B (25kA) / N (36kA) / S (50kA) / H (65/70kA) / G (85kA) |
|
5. Protection Release Type |
Thermal-Magnetic (Standard) or ST110-H Electronic Microprocessor |
|
6. Selected Accessories |
Shunt release (voltage), Auxiliary/Alarm contact, Rotary handle, Motorized drive, DIN clip |
|
7. Target Trade Terms |
FOB Ningbo / Shanghai, CIF destination port, or EXW |
Looking for a reliable SACE Moulded Case Circuit Breaker supplier? Contact CDADA to discuss DAM1 Series models, optional motorized mechanisms, technical requirements and factory-direct supply.
Send an InquiryAddress
No. 171, Yezhuang Road, Zhuangxing Town, Fengxian District, Shanghai, China
Tel
Unlock Your Custom Electrical Solution in 24 Hours!
Why Inquire with a Top-Tier Chinese Manufacturer?
✅ Direct Factory Pricing
Cut middleman costs! As a ISO 9001-certified factory in China, we deliver premium MCCBs, MCBs, and solar DC breakers at competitive rates—backed by CE, KEMA, and ASTA certifications.
✅ 40+ Years of OEM/ODM Expertise
Modify casings, labels, or technical specs effortlessly. Our R&D team (60+ patents) handles:
Custom voltage/current ratings
Branded packaging
Fast prototyping (samples in 7 days)
✅ 3 Million+ Units Annual Capacity
No order too large or urgent! Our 52,400㎡ plant guarantees:
◆ 15-day lead times for bulk orders
◆ Flexible MOQs
◆ Strict ASTM/UL testing
✅ Global Compliance, Zero Hassle
We solve export barriers for 45+ countries:
RoHS/REACH documentation
Region-specific certifications
Solar DC breakers for EU green projects