Products
MCCB with Leakage Protection
  • MCCB with Leakage ProtectionMCCB with Leakage Protection
  • MCCB with Leakage ProtectionMCCB with Leakage Protection

MCCB with Leakage Protection

Model:DAM1L Series
Source CDADA MCCB with Leakage Protection (DAM1L Series) from Shanghai DADA Electric, as a reliable factory, we can offer technical support and OEM services. 4P, 16–500A, adjustable earth leakage (30mA–1000mA), CE/CB/SEMKO certified. Ideal for fire & personal safety in buildings, tunnels & industrial sites.

Enhance electrical safety beyond overload and short-circuit protection with the CDADA DAM1L Series MCCB with Leakage Protection an integrated moulded case circuit breaker with built-in residual current (RCD/ELCB) functionality. Designed by the professional manufacturer Shanghai DADA Electric CO., LTD to international standards, this leakage MCCB 4P combines high-performance power distribution with life- and fire-saving ground fault detection.

Rated from 10A to 500A at 400V/415V, it offers adjustable residual operating current (30mA–1000mA) and optional time delay—enabling tailored protection for personal safety (≤30mA) or fire prevention (100mA–500mA+). With multi-phase powered electronics, it remains operational even if one phase fails or voltage drops to 50V, ensuring unmatched reliability in critical infrastructure like tunnels, high-rises, transportation hubs, and industrial plants.

MCCB with Leakage Protection

Key Specifications

Model: DAM1L Series – Earth Leakage MCCB (CBR-type MCCB)

Poles: 4P (standard; 3P available on request)

Rated Current (In): 10A – 500A

Rated Voltage: 400V / 415V AC, 50Hz

Insulation Voltage (Ui): 400V (≤160A), 690V (>250A)

Residual Current Settings (I△n): 30mA, 100mA, 300mA, 500mA, 1000mA

Adjustability: On-site adjustment of I△n and trip time (instantaneous or delayed)

Breaking Capacity Types:

B Type: Basic (Inm < 100A)

S Type: Standard

H Type: High breaking (>160A)

Certifications: CE, CB, SEMKO


Key Features:

★ Multi-phase powered RCD circuit → works down to 50V

★ Separate main & arcing contacts

★ Push-to-trip test button

★ Adjustable magnetic setting (0.8–1.0×In)

★ Strong EMI/RFI anti-interference capability

★ Full accessory range: shunt trip, auxiliary/alarm contacts, rotary handle


Technical data sheet

Earth-Leakage Circuit Breakers(ELCB)



Model

DAM1-125L

DAM1-160L

Breaking Capacity Code

B

N

S

B

N

S

Rated Current of Frame size- Inm (A)

125A

160A

Rated Current-In(40,50 or 55℃) (A)

10 - 12,5 - 16 - 20 - 25 - 32(30) - 40 - 50 - 63(60) - 80 - 100 - 125A

10- 12,5-16-20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 -125 - 160(150)A

Ui (V)

690V

690V

Ue (V)

400V

400/415V

Number of Pole

4P

4P

Icu (KA)

25

35

50

25

35

50

Ics(KA)

12.5

17.5

37.5

12.5

26.25

37.5

Icm(peak)/cos ф (KA)

40/0.3

73.5/0.25

105/0.25

41/0.3

73.5/0.25

110/0.25

(I△m)KA/cosф

9/0.5

19/0.5

Residual current threshold(mA)

100-300-500

100-300-500

Time delay(ms)

50-500-800

50-500-800

Uimp (V)

10000

8000

Dielectric Propery (V)

2500

3000

lonization distance (mm)

≤30/0

≤30/0

Endurance

Total Cycles

8000

8000

Electrical Life

1000

1000

Mechanical Life

7000

7000

Category (EN 60947-2/IEC 60947-2)

Main circuit

A/0

A/0

Auxiliary circuit

AC-15

AC-15

Under Voltage Release

Shunt Release

Auxiliary Contact

Alarm Contact

Auxiliary Contact and Alarm Contact

Handle Operation Mechanism

Electrical Operastion Mechanism

Terminal cover



Phase seperator



MCCB with Leakage Protection

W (mm)

3P

-

-

4P

101

120

L (mm)

3P

-

-

4P

155

120

H (mm)

3P

-

-

4P

70

70

Weight

Fixed version 3P/4P

-

-

Plug-in version 3P/4P

-

-

Draw out version 3P/4P

-

-

Why Choose CDADA MCCB with Leakage Protection?

★ True Integrated Safety

Unlike add-on RCD modules, the DAM1L has built-in, factory-calibrated leakage protection—ensuring perfect coordination and eliminating compatibility issues.

★ Multi-Phase Power for RCD Circuit

Early RCDs failed if one phase was lost. CDADA’s design uses all phases to power the protection electronics, so it keeps working even during phase loss or severe undervoltage.

★ Dual Protection Goals in One Device

◆ 30mA: Meets IEC requirements for personal shock protection

◆ 100mA–1000mA: Prevents insulation degradation fires from small, persistent ground faults

★ Field-Adjustable for Real-World Conditions

Fine-tune sensitivity and time delay to avoid nuisance tripping in wet environments (e.g., car washes, farms) while maintaining safety.

★ Industrial-Grade Reliability

High breaking capacity (H-type), robust arc separation, and IP20+ terminal protection make it suitable for harsh commercial and industrial settings.

★ Global Compliance, Local Value

Certified for Europe (CE/CB), Nordic countries (SEMKO)—ideal for export projects—with competitive pricing from a trusted Chinese manufacturer.


MCCB with Leakage ProtectionMCCB with Leakage ProtectionMCCB with Leakage Protection

★ Our manufacturing facility is certified under the ISO9001:2015 Quality Management System.

MCCB with Leakage Protection

Typical Applications

MCCB with Leakage ProtectionHigh-Rise Residential: Main incomer or floor panels (300mA for fire risk reduction)

MCCB with Leakage ProtectionTunnels & Subways: Critical infrastructure requiring fail-safe leakage detection

MCCB with Leakage ProtectionHospitals & Schools: 30mA protection in wet areas (labs, restrooms)

MCCB with Leakage ProtectionIndustrial Plants: Motor feeders with ground fault monitoring

MCCB with Leakage ProtectionConstruction Sites: Temporary power distribution with personnel protection


FAQ

Q1: What’s the difference between a standard MCCB and an MCCB with leakage protection?

A1: A standard MCCB only protects against overload and short circuits. The DAM1L adds residual current (earth leakage) detection—tripping when current leaks to ground (e.g., through a person or damaged insulation), preventing electric shock or fire.


Q2: Can I use a 100A MCCB RCD for personal protection?

A2: Only if set to 30mA. The rated current (100A) defines load capacity; the residual setting (I△n) defines safety function. For shock protection, I△n must be ≤30mA, regardless of In.


Q3: Why does the RCD circuit need multi-phase power?

A3: If powered by only one phase, a single-phase failure would disable leakage protection. CDADA’s multi-phase design ensures the RCD remains active even during phase loss or low voltage (down to 50V)—critical for safety continuity.


Q4: Is the 4P leakage MCCB suitable for TT or TN-S systems?

A4: Yes—it’s designed for TT, TN-S, and IT systems. The 4P design breaks all phases and neutral, essential for TT systems where neutral isn’t reliably grounded upstream.


Q5: Why choose CDADA over modular RCD + MCCB combinations?

A5: CDADA DAM1L offers:

● Smaller footprint (integrated vs. two devices)

● Guaranteed coordination (no mismatch risk)

● Lower cost & wiring complexity

● Higher reliability (single sealed unit)

● On-site adjustability not possible with fixed-sensitivity RCDs

Hot Tags: MCCB with Leakage Protection, China, Manufacturer, Supplier, Factory
Send Inquiry
Contact Info

Unlock Your Custom Electrical Solution in 24 Hours!

Why Inquire with a Top-Tier Chinese Manufacturer?

✅ Direct Factory Pricing

Cut middleman costs! As a ISO 9001-certified factory in China, we deliver premium MCCBs, MCBs, and solar DC breakers at competitive rates—backed by CE, KEMA, and ASTA certifications.

✅ 40+ Years of OEM/ODM Expertise

Modify casings, labels, or technical specs effortlessly. Our R&D team (60+ patents) handles:

Custom voltage/current ratings

Branded packaging

Fast prototyping (samples in 7 days)

✅ 3 Million+ Units Annual Capacity

No order too large or urgent! Our 52,400㎡ plant guarantees:

◆ 15-day lead times for bulk orders

◆ Flexible MOQs

◆ Strict ASTM/UL testing

✅ Global Compliance, Zero Hassle

We solve export barriers for 45+ countries:

RoHS/REACH documentation

Region-specific certifications

Solar DC breakers for EU green projects

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.Privacy Policy
RejectAccept