Products

China Professional Miniature Circuit Breaker Factory

We invite you to order high-quality Miniature Circuit Breakers from CDADA. As a professional manufacturer with decades of experience, we offer a comprehensive range of configurations and support OEM customization services to ensure compliance with various domestic Chinese and international certifications and standards. Please feel free to contact us for a quotation.


What Is a Miniature Circuit Breaker?

A Miniature Circuit Breaker (MCB) is a compact, resettable low-voltage protection device designed to safeguard electrical circuits from overloads and short circuits. Operating at rated voltages up to 240/415V AC (50/60Hz) with current ratings from 0.5A to 125A, MCBs serve as the primary circuit protection device in residential, commercial, and light industrial electrical distribution systems.

The MCB represents a fundamental advancement over traditional fuses, offering automatic tripping upon fault detection and manual reset capability once the fault is cleared—eliminating component replacement and reducing maintenance costs. Each MCB features a specific current rating matched to the protected circuit, ensuring precise protection coordination.

 

MCB Product Categories & Configurations

Classification

Type

Current Range

Key Characteristics

Tripping Characteristic (Curve)

Type B

0.5A – 63A

3-5×In instantaneous trip, low inrush loads (lighting, resistive heating)

Type C

0.5A – 125A

5-10×In trip, moderate inrush (motors, air conditioners, small appliances)

Type D

0.5A – 63A

10-20×In trip, high inrush (transformers, large motors, welding equipment)

Type K

0.5A – 63A

8-12×In trip, commercial/industrial motor loads

Type Z

0.5A – 40A

2-3×In trip, sensitive electronic equipment, semiconductor protection

Pole Configuration

Single-Pole (SP)

0.5A – 63A

Phase protection in single-phase circuits

Double-Pole (DP)

0.5A – 63A

Phase + neutral protection, common trip bar

Triple-Pole (TP)

0.5A – 125A

Three-phase protection, industrial distribution

Four-Pole (4P)

0.5A – 125A

Three-phase + neutral, common trip mechanism

Breaking Capacity

Standard (S)

3kA – 6kA

Domestic installations, low fault level networks

Enhanced (H)

10kA

Commercial buildings, medium fault levels

High (G)

15kA – 25kA

Industrial mains, high fault capacity

Mounting Standard

DIN Rail (IEC 60715)

All ratings

35mm top-hat rail (TH35), quick snap-on installation

Panel Mount

0.5A – 63A

Screw-fixed base, legacy installations

Current Rating Series (Preferred Values): 0.5A,1A,2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A

 

Core Functions & Protection Capabilities

Dual-Element Protection Mechanism

Function

Actuation Principle

Technical Parameters

Overload Protection (Thermal)

Bimetallic strip heat expansion

1.05×In: No trip (2h), 1.3×In: Trip ≤1h (In≤32A), ≤2h (In>32A), 1.45×In: Trip <1h

Short-Circuit Protection (Magnetic)

Solenoid plunger instantaneous

Type B: 3-5×In, Type C: 5-10×In, Type D: 10-20×In, <20ms operation

Isolation Function

Positive contact separation

Suitability for isolation per IEC 60898-1, contact gap verification

Trip Indication

Mechanical flag/window

Distinct ON/OFF position, trip-free mechanism prevents closure on fault

Advanced Design Features

Modern MCBs incorporate sophisticated engineering elements:

Quick-make, quick-break mechanisms: Independent of handle operation speed, ensuring consistent contact closure

Trip-free design: Prevents manual closure during sustained fault conditions

Line-load reversibility: Input/output terminals interchangeable for installation flexibility


Application Environments & Use Cases

Installation Environment

Specific Application

Typical Specifications

Residential Buildings

Lighting circuits, socket outlets, HVAC, water heaters

6A-32A Type B/C, 6kA Icn, DIN rail mounting

Commercial Offices

Distribution boards, computer equipment, UPS circuits

10A-63A Type C, 10kA Icn, 4-pole for 3-phase

Retail & Hospitality

Shop lighting, refrigeration, kitchen equipment

16A-40A Type C, 10kA, common trip for multi-pole

Industrial Control Panels

Machine tools, motor control circuits, automation

10A-63A Type D, 15kA, high mechanical endurance

Infrastructure

Metro stations, airports, hospitals, data centers

32A-125A Type C, 25kA, current limiting Class 3

Renewable Energy

Solar string protection, battery systems, inverters

10A-63A DC-rated (IEC 60898-2), 250V/500V/1000V DC

Marine & Offshore

Ship distribution, offshore platforms

Tropicalized (T2), corrosion-resistant, 55°C ambient

 

Manufacturing Process & Production Workflow

High-Volume Precision Manufacturing Sequence

Raw Material IQC → Thermoplastic Injection Molding → Contact System Stamping → Bimetallic Element Assembly → Magnetic Coil Winding → Arc Chute Integration → Mechanism Assembly → Calibration & Testing → Final QC → Packaging

Critical Manufacturing Stages

Stage

Process Details

Quality Control Points

Housing Injection Molding

High-impact thermoplastic (PA66, PBT) with 30% glass fiber, 280-320°C melt temperature, 800-1200 bar injection pressure

Dimensional tolerance ±0.05mm, impact strength >7 kJ/m², tracking index >600V, UL 94 V-0 flammability

Contact Stamping & Plating

Silver-nickel (AgNi 90/10) or silver-cadmium oxide contacts, progressive die stamping, barrel plating 8-12μm silver

Hardness HV 80-120, contact resistance <100μΩ, plating thickness XRF verification

Bimetallic Element Production

Inconel/passivated steel composite, precision rolling, heat treatment for deflection characteristics

Deflection rate 0.15-0.25mm/°C, calibration at 20°C reference, ±3% batch consistency

Magnetic Coil Manufacturing

Copper wire (0.3-0.8mm diameter), automated winding, vacuum varnish impregnation

Turns count ±1%, DC resistance ±5%, insulation resistance >100MΩ

Arc Chute Assembly

Steel splitter plates (0.5mm), ceramic arc grids, optimized deionizing chamber geometry

Magnetic flux verification, dielectric strength 2.5kV, dimensional ±0.02mm

Mechanism Integration

Spring steel charging system, toggle mechanism, trip-free override, energy storage springs

Mechanical endurance 20,000 cycles, trip force 3-8N, toggle reliability

Final Calibration

Automated time-current testing at 1.05×In, 1.25×In, 5×In (or curve-specific)

Trip time ±20% tolerance, instantaneous trip verification, marking permanence

 

Primary Raw Materials & Component Specifications

Component

Material Specification

Supplier Standards

Key Properties

Moulded Housing

PA66 GF30 (polyamide 66, 30% glass fiber) or PBT GF30

IEC 60664-1, UL 94 V-1

Tracking index >600V, heat resistance 160°C, impact strength >7 kJ/m², halogen-free available

Operating Handle

PC/ABS blend or PA66

ISO 527

Tensile strength >50MPa, UV stabilized, colorfast

Fixed/Moving Contacts

Electrolytic copper (Cu-ETP C11000) + AgNi 90/10 or AgCdO plating

ASTM B152

Conductivity ≥100% IACS, arc erosion resistance, anti-welding

Bimetallic Strip

Inconel 718/passivated steel composite (ASTM TM2) or brass/steel

ASTM B388

Deflection rate 0.2mm/°C, stability ±3% over 20 years, creep resistance

Magnetic Coil

Enameled copper wire (Class F 155°C or Class H 180°C)

IEC 60317

Breakdown voltage >3kV, solderability 390°C/2s, flexibility

Arc Splitter Plates

Cold-rolled steel SPCC-SD (0.5mm) with ceramic coating

JIS G 3141

Magnetic permeability >2000, heat resistance >1000°C, arc quenching

Operating Springs

Oil-tempered carbon steel SWP-B or stainless steel 301

JIS G 3522

Fatigue life >50,000 cycles, tensile strength 1800-2200MPa

Terminals

Brass C36000 or copper C11000 with tin plating (5-8μm)

ASTM B16

Current density 1.0-1.2 A/mm², torque withstand 1.5-2.5Nm, corrosion resistance

Mounting Clip

Spring steel 65Mn or stainless steel 304

GB/T 1222

Clamp force 50-100N, DIN rail compatibility (EN 60715) 

 

Standards Compliance & Testing Protocols

International Standards Framework

Standard

Scope

Applicable Ratings

IEC 60898-1

Circuit breakers for AC operation (household & similar)

Global baseline for AC MCBs up to 125A, 415V

IEC 60898-2

Circuit breakers for AC and DC operation

DC-rated MCBs for solar, battery, rail applications

EN 60898-1

European harmonized version

CE marking, EU market compliance

IEC 60947-2

Low-voltage switchgear - Circuit-breakers

Industrial MCBs >80A, higher breaking capacities

GB/T 10963.1

Chinese national standard equivalent

CCC certification, China market

Mandatory Type Tests (IEC 60898-1)

Test Category

Specific Test

Acceptance Criteria

Marking & Documentation

Indelibility of marking

Permanent after solvent wiping, temperature cycling

Mechanical Integrity

Reliability of screws, connections, terminals

No loosening after vibration, torque withstand

Safety

Protection against electric shock

IP20 minimum, finger-proof terminals

Dielectric Properties

Power-frequency withstand (2kV/1min), impulse (6kV)

No breakdown, no flashover

Temperature Rise

Continuous current at 40°C ambient

Terminals ≤60K, case ≤40K

28-Day Test

Sustained 1.13×In loading

No trip, no degradation

Tripping Characteristics

Conventional time-current verification

1.05×In: no trip (2h), 1.3×In/1.45×In: trip within limits

Mechanical Endurance

20,000 no-load operations

<5% parameter drift, no failure

Electrical Endurance

4,000 load operations at rated current

Contact wear <50%, trip characteristics maintained

Short-Circuit Breaking

Icn (rated), Ics (service) verification

3 operations, successful interruption, dielectric recovery

Environmental

Mechanical shock, impact, heat, fire, rusting

Functional after conditioning, no safety degradation 

 

Factory Quality Control & Inspection Standards

Incoming Material QC (IQC)

Material

Inspection Items

Sampling Plan

Equipment

Thermoplastic granules

Glass content, viscosity, moisture, color

Per batch, COA verification

Melt flow indexer, moisture analyzer, spectrophotometer

Copper wire (contacts)

Purity ≥99.9%, conductivity, annealing

AQL 0.65

Spectrometer, conductivity meter

Silver plating solution

Metal concentration, pH, impurities

Daily monitoring

Atomic absorption spectrometer

Bimetallic strip

Deflection rate, resistance, stability

Per batch, sample testing

Thermal oven, deflection measurement

Enameled wire

Diameter, insulation thickness, breakdown voltage

AQL 1.0

Micrometer, dielectric tester

Spring steel

Tensile strength, fatigue resistance, forming

Per batch

Tensile machine, fatigue tester

In-Process Quality Control (IPQC)

Station

Control Parameters

Frequency

Method

Injection molding

Temperature 280-320°C, pressure 800-1200 bar, cycle time

Every cycle

SCADA monitoring, SPC charts

Contact stamping

Dimension ±0.02mm, burr <0.01mm, plating thickness

Every 30 minutes

Optical comparator, XRF analyzer

Bimetal calibration

Deflection at reference temperature, creep test

Every 100 units

Automated calibration station

Coil winding

Turns count, tension control, layer uniformity

Every unit

Automated winding machine with feedback

Mechanism assembly

Toggle force, trip-free function, contact gap

Every unit

Force gauge, automated test bench

Final assembly

Torque marking, contact alignment, handle operation

Every unit

Vision system, functional tester

Final Quality Control (FQC) & Outgoing QC (OQC)

Test Item

Standard

Sample Size

Dielectric withstand voltage

2kV AC/1min

100%

Insulation resistance

>100MΩ @ 500V DC

100%

Contact resistance

<100μΩ per pole

100%

Tripping characteristics

1.05×In (no trip), 1.3×In (trip), 5×In (instantaneous)

 

100%

Mechanical operation

5 ON-OFF cycles, trip-free verification

100%

Clearance between open contacts

≥3mm (per IEC 60898-1)

100%

Visual & dimensional inspection

Zero defects on critical dimensions

100%

Marking permanence

Solvent wiping, abrasion test

AQL 1.0

Packaging integrity

Drop test, vibration (ISTA 3A), labeling

Per lot 

 

Production Infrastructure & Manufacturing Capability

Advanced Production Equipment

Equipment Category

Machine Specification

Function

Capacity

Injection Molding

120-ton thermoplastic injection press (Arburg/Engel) with robotic handling

MCB housing, cover, arc chamber production

5,000 housings/day

Progressive Stamping

60-ton high-speed press (Bruderer/Yamada Dobby) with die protection

Contact stamping, terminal forming

30,000 contacts/day

Surface Treatment

Automated barrel plating line (silver, tin)

Contact plating thickness 8-12μm

5,000 kg/day

Assembly

High-speed assembly

Mechanism assembly, calibration, testing

3,000 units/day per line

Testing Equipment

Automated primary injection test set (3-125A, 10,000A fault capacity)

Time-current curve verification

500 units/hour

Mechanical endurance tester (20,000 cycles, IEC 60898-1 Clause 9.11)

Life testing, wear monitoring

200 units simultaneous

EMC test chamber (for electronic accessories)

Immunity/emission testing

100 units/day

Production Capacity & Lead Times

Product Category

Monthly Capacity

Standard Lead Time

Urgent Order Capability

Standard MCB (0.5A-63A, SP/DP)

1,000,000 units

3-4 weeks

3 days (stock components)

Industrial MCB (80A-125A, TP/4P)

200,000 units

3-4 weeks

5 days

DC MCB (IEC 60898-2)

100,000 units

3-4 weeks

5 days

Custom configurations (special curves, accessories)

Project basis

4-6 weeks

2 weeks

Engineering & Technical Team Structure

Department

Personnel

Expertise

Responsibilities

R&D Engineering

5 engineers

Low-voltage protection, material science, electromagnetic design, automation

New product development (B/C/D/K/Z curves), customization, patent portfolio (30+ patents)

Process Engineering

18 engineers

Injection molding, precision stamping, plating, lean manufacturing

Production line optimization, SOP documentation, yield improvement (>99%), automation integration

Testing & Validation

12 engineers

High-volume testing, environmental simulation, reliability engineering

Type testing coordination, routine test automation, failure analysis, certification management

Quality Assurance

30 technicians

ISO 9001, IATF 16949, statistical process control (SPC), metrology

Supplier audit, process audit, corrective action management, calibration laboratory

Application Engineering

8 engineers

Residential/commercial electrical design, selective coordination, field support

Customer technical support, distribution board design, training programs 

 

Certifications & Compliance Documentation

Certification

Issuing Body

Scope

Validity

ISO 9001:2015

TÜV SÜD / SGS / Bureau Veritas

Quality management system

Annual surveillance

IEC 60898-1 Type Test

Intertek

Product safety & performance

Per product series

CE Marking

Notified Body

EU market access

Design-dependent

CCC (China)

CQC

Chinese compulsory certification

5-year validity

CB Scheme

IECEE

International certification

Per product series

SEMKO (Sweden)

Intertek

Nordic market safety approval

Per product series

 

Why Our MCB Manufacturing Stands Apart

Our production facility represents 40 years of specialization in miniature circuit breaker manufacturing, delivering products that exceed global standards through:

 

High-volume precision manufacturing: Automated lines producing 1,000,000+ units monthly with <50ppm defect rates

Vertical integration: In-house housing injection molding, contact stamping/plating, and DIN rail production ensuring complete supply chain control

Advanced testing infrastructure: $2M+ invested in automated primary injection testing, mechanical endurance verification (20,000 cycles), and EMC compliance

Global certification strategy: Multi-standard compliance (IEC 60898-1, EN, GB, ) enabling seamless market entry across 120+ countries

Customization capability: From specialized tropical formulations (T2, 55°C ambient) to DC-rated versions (250V/500V/1000V) and unique curve characteristics

 

For technical specifications, distribution board design support, selective coordination studies, or factory audit scheduling, our engineering team provides direct consultation to ensure your residential, commercial, or industrial electrical installations meet both protection requirements and long-term reliability objectives.

View as  
 
4.5kA 6kA Miniature Circuit Breaker

4.5kA 6kA Miniature Circuit Breaker

CDADA is the professional manufacturer of 4.5kA 6kA Miniature Circuit Breaker, certified with CCC and ISO9001 for safe circuit protection. It uses flameretardant shell and precise thermal-magnetic tripping, is easy to mount on DIN rail and simple to maintain. It combines stable performance with long service life, ideal for residential, commercial and industrial power distribution.
1P 6kA AC Miniature Circuit Breaker

1P 6kA AC Miniature Circuit Breaker

Feel free to contact CDADA, and get our 1P 6kA AC Miniature Circuit Breaker with factory direct price, offering reliable overload and short-circuit protection with compact DIN-rail design. This product features precise thermal-magnetic tripping and clear status indication, easy to install and maintain. It delivers stable performance for residential and light commercial circuits, ensuring safe power supply with long service life.
10kA AC Miniature Circuit Breaker

10kA AC Miniature Circuit Breaker

10KA AC Miniature Circuit Breaker is an advanced and high-performance product, offered by the reliable manufacturer CDADA, with CE, CB, ASTA, SEMKO, and ROHS certified. 1P/2P/3P, 6–63A, ideal for industrial & commercial panels. High 10kA breaking capacity, –40°C to +50°C operation, silver-alloy contacts. OEM & bulk orders welcome.
6kA AC Miniature Circuit Breaker

6kA AC Miniature Circuit Breaker

Buy 6kA AC Miniature Circuit Breaker (DAB6-63) from Shanghai DADA Electric, we are a reliable manufacturer and supplier. This product is CE & CB certified, 1P/2P/3P/4P available, with B/C/D curves for home & light commercial use. Wide temp range (-40°C to +50°C), low thermal loss terminals. Ideal for residential panels.
CDADA is a Miniature Circuit Breakers manufacturer and supplier in China. Our factory serves diverse industries such as power systems, building automation, and industrial manufacturing, offering flexible OEM/ODM solutions.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept